High-temperature charge-mode piezoelectric accelerometers

Keep the sensing element at the test point and the electronics in a verified cooler zone. Configure a passive charge-output sensor, its hot-zone cable and the remote conditioning as one measurement chain.

Content reviewed

PZA-CHG / INSTALLATION DECISION

The hot probe and the remote electronics have different limits.

A charge-mode probe separates the sensing element from the electronics. Request the continuous temperature, dwell and thermal transients at the mounting surface, then specify the insulation resistance at that temperature. A room-temperature sensitivity alone does not describe the hot chain.

Above the confirmed rating of a flexible cable or connector, review a mineral-insulated hardline section, termination and minimum bend radius. The cooler low-noise coax segment and the conditioner must each remain inside their own limits. A fixed distance of two metres is not a temperature specification.

Annular shear and compression constructions respond differently to mounting strain and thermal transients. Request the exact mounting drawing and base-strain/temperature data for the proposed configuration. Cryogenic operation is a separate minimum-temperature review.

Charge probe, hot-to-cool cable transition and remote conditioner with separate local temperatures
Original engineering concept. Any numerical example is illustrative; actual hardware and installed performance require confirmation.
Can the +480°C request use ordinary +260°C PTFE coax in the hot zone?

No. Review the hot section separately. A cooler PTFE section may be proposed after its actual local temperature, connector and insulation have been checked.

Is PZA-CHG-400 automatically interchangeable with Endevco 2273AM1?

No. The PZA code is a request profile. Confirm sensitivity, temperature-dependent insulation, complete suffix, housing, mounting, cable and calibration before approving a substitution.

Which conditioner belongs with a high-temperature charge probe?

Match the sensor’s hot-state resistance, peak charge, polarity and measurement window to a suitable charge amplifier or converter, then verify the receiving DAQ input.

Read the original-model reference and approval checks →

PZA-CHG / SELECT A REQUEST PROFILE

Compare +260°C, +400°C and special +480°C requests.

Each PZA identifier describes a configuration to quote. The requested targets below remain subject to supply, drawing and calibration review.

PZA-CHG-260

260°C charge vibration request

Engine and turbine housings; sensitivity, insulation and mounting reviewed together.

Requested output / axes
Charge · pC/g · 1 axis
Connection review
Single-ended coaxial charge path
  • Up to +260°C local probe temperature
  • 10 pC/g nominal request; other sensitivities by review
  • 11g mass target; stud or isolated through-hole drawing required
Original references and differences to review
Endevco 2221F ↗

Original datasheet values. The -R store listing excludes a cable.

PCB 357B03 ↗

Low-frequency response is determined by the external conditioner. The +5% limit is not a ±5% flat-band statement.

B&K 4371 ↗

See the exact 4371 or V-type column in the original sheet.

PCB 357B11 ↗

Buyer-reference entry for manual review.

Request PZA-CHG-260 ↗
PZA-CHG-400

400°C class charge request

Separate legacy suffixes, hot-state insulation and the hardline transition.

Requested output / axes
Charge · pC/g · 1 axis
Connection review
Single-ended coaxial charge path
  • Approximately +399°C test-point requirement
  • Charge sensitivity and housing alloy to confirm
  • Mineral-insulated cable length and termination review
Original references and differences to review
Endevco 2273A ↗

The index identifies original-manufacturer alternatives; it does not approve a PZA substitute.

Endevco 2273AM1 ↗

The index identifies original-manufacturer alternatives; it does not approve a PZA substitute.

Request PZA-CHG-400 ↗
PZA-CHG-480

480°C special charge request

Special-temperature feasibility review before choosing a crystal or cable.

Requested output / axes
Charge · pC/g · 1 axis
Connection review
Connector / topology to review
  • Up to +480°C is a request target, not a released rating
  • Sensitivity, mass, insulation and lifetime remain unspecified
  • No automatic match to a +399°C original model
Original references and differences to review

No original model is nominated for this special request. Provide a controlled baseline and a test specification.

Request PZA-CHG-480 ↗
PZA-CHG / CONFIGURATION REVIEW

Define the test envelope.

Turbine housings, engine blocks, exhaust structures and hot vibration fixtures.

Requested options for review — these are configuration targets, not released specifications.
Temperature request−70°C to +260°C; special +480°C configurations reviewed separately
Charge sensitivity request3, 10, 30 or 100 pC/g; range and temperature dependent
Connection request10-32 coaxial or 2-pin; pinout and insulation to confirm

Range, temperature, sensitivity and bandwidth combinations require model-specific confirmation, controlled drawings and calibration requirements.

Before you select

  1. Specify continuous temperature, dwell time, thermal transients and local cable temperatures.
  2. Check insulation resistance at the operating temperature before selecting a charge converter.
  3. For extreme hot zones, review mineral-insulated hardline separately from the cooler PTFE cable segment.

Original-model review candidates
PCB 357B03 / 357B11 / 357A08; B&K 4371 / 4393; Endevco 2221F / 2273A

Review replacement criteria →

Confirm the PZA-CHG output before connecting the DAQ.

Three separate chains: charge sensor to remote charge amplifier or converter, voltage sensor to IEPE input, and piezoresistive bridge to excitation and differential DC input
Conceptual signal paths. Actual electrical and thermal limits require a configuration review.
PZA-CHG / QUOTE & CAD

Send the PZA-CHG configuration, channels and document scope.

Accessories are optional quotation requests. Selection and final pricing follow the electrical, mounting and temperature review.

PZA engineering request
Optional accessories — quote by configuration

Review hot-state insulation and charge headroom. PTFE coax is a cooler cable segment; extreme hot zones need a separately verified cable. Differential charge cannot use the default single-ended coax/converter path.

Documents to request
Open prefilled email ↗

Current request: PZA-CHG custom configuration. Changing output, topology or temperature may require a custom review.

Email [email protected]. If your desktop mail app shortens a long brief, use copy or download. No attachments are uploaded by this form.

Preview the complete engineering brief
PZA engineering RFQ
Name: Not provided
Company / lab: Not provided
Reply email: Not provided
Family: PZA-CHG
PZA request profile: Unspecified
Sensing technology: High-temperature charge piezoelectric
Output: Charge · pC/g
Axes / peak g: Specify in test brief
Independent channels: To confirm
Local operating temperature: Cryogenic / other — specify local temperatures
Conditioning: Charge-to-IEPE conversion
Connector / topology: Single-ended coaxial charge path
Converter polarity: review
Original model: Not provided
Original source: No exact original reference matched; manual review
Reference status: No exact source match
Quantity: 1
Source: /high-temperature-charge-piezoelectric-accelerometers
Optional accessories: PZA-422 inline charge converter — gain and source resistance review; 3m low-noise PTFE coax — cooler segment, up to +260°C option
Documents requested: None
No PZA hardware configuration assumed.
Configuration review only; compatibility, temperature, calibration, prices and delivery require confirmation.
Test brief:
Not provided
CAD / CALIBRATION / QUOTATION

Request the documents that close the engineering review.

Temperature-dependent sensitivity and insulation, cable termination, mounting surface and local hot/cold zones.

Controlled datasheet & CAD

Ask for the quoted configuration, revision, complete dimensions, tolerances, mounting thread, cable and connector. STEP availability is confirmed against that exact configuration.

Calibration & traceability scope

State reference frequency, amplitude, excitation and temperature. Request available sensitivity, capacitance, transverse response and frequency/temperature records. A named calibration standard alone is not a test result.

Formal quote / PI inputs

Include sensor and channel counts, accessories, calibration scope, destination, delivery window and required documents. Prices and availability are confirmed in the quotation.

No released PZA CAD, measured certificate or commercial quote is supplied by these concept pages. Select the required documents in the RFQ; we will confirm what can be provided for the proposed configuration.

Request CAD and calibration scope ↗